TY - JOUR
T1 - Bacterial inactivation, photoreactivation and dark repair post flow-through pulsed UV disinfection
AU - Fitzhenry, Kelly
AU - Clifford, Eoghan
AU - Rowan, Neil
AU - Val del Rio, Angeles
N1 - Publisher Copyright:
© 2021 The Author(s)
PY - 2021/6
Y1 - 2021/6
N2 - Pulsed UV (PUV) technology is accepted commercially for disinfection within the food packaging industry, but has yet to be deployed by the water/wastewater sector. This is partly due to a lack of robust, independently validated data for submerged or flow-through treatment applications. This study evaluated the efficacy of PUV for water disinfection under flow-through conditions. Bacterial pathogens of interest in the food and water/wastewater sector, namely Escherichia coli, Staphylococcus aureus and Listeria innocua (surrogate for L. monocytogenes) were used to investigate the potential for photoreactivation and/or dark repair post PUV flow-through disinfection. A continuous-flow low-pressure UV was also analysed under similar experimental conditions. Bacterial inactivation via flow-through PUV was dependant on energy output with E. coli exhibiting greatest sensitivity to PUV treatment (5.3 log 10 inactivation after treatment at 1539 mJ/cm 2 - output in UV range < 300 nm); L. innocua exhibited the highest PUV resistance (3.0 log 10 inactivation after treatment at 1539 mJ/cm 2 – output in UV range < 300 nm) under similar treatment conditions. Greater photoreactivation occurred at lower PUV outputs for both S. aureus and E. coli after flow-through PUV treatment. Thus exposure of treated bacteria to natural light, immediately post flow-through PUV treatment, should be avoided to minimise photoreactivation. The LPUV demonstrated inactivation of all bacteria below the limit of detection (1 CFU/mL) and inhibited the occurrence of photoreactivation. This study highlights the importance of considering bacterial repair potential and the need for further development of PUV technology for such applications.
AB - Pulsed UV (PUV) technology is accepted commercially for disinfection within the food packaging industry, but has yet to be deployed by the water/wastewater sector. This is partly due to a lack of robust, independently validated data for submerged or flow-through treatment applications. This study evaluated the efficacy of PUV for water disinfection under flow-through conditions. Bacterial pathogens of interest in the food and water/wastewater sector, namely Escherichia coli, Staphylococcus aureus and Listeria innocua (surrogate for L. monocytogenes) were used to investigate the potential for photoreactivation and/or dark repair post PUV flow-through disinfection. A continuous-flow low-pressure UV was also analysed under similar experimental conditions. Bacterial inactivation via flow-through PUV was dependant on energy output with E. coli exhibiting greatest sensitivity to PUV treatment (5.3 log 10 inactivation after treatment at 1539 mJ/cm 2 - output in UV range < 300 nm); L. innocua exhibited the highest PUV resistance (3.0 log 10 inactivation after treatment at 1539 mJ/cm 2 – output in UV range < 300 nm) under similar treatment conditions. Greater photoreactivation occurred at lower PUV outputs for both S. aureus and E. coli after flow-through PUV treatment. Thus exposure of treated bacteria to natural light, immediately post flow-through PUV treatment, should be avoided to minimise photoreactivation. The LPUV demonstrated inactivation of all bacteria below the limit of detection (1 CFU/mL) and inhibited the occurrence of photoreactivation. This study highlights the importance of considering bacterial repair potential and the need for further development of PUV technology for such applications.
KW - Bacterial disinfection
KW - Cell injury
KW - Disease mitigation
KW - Pulsed UV
KW - Ultraviolet applications
KW - Wastewater treatment
UR - http://www.scopus.com/inward/record.url?scp=85104486332&partnerID=8YFLogxK
U2 - 10.1016/j.jwpe.2021.102070
DO - 10.1016/j.jwpe.2021.102070
M3 - Article
AN - SCOPUS:85104486332
SN - 2214-7144
VL - 41
JO - Journal of Water Process Engineering
JF - Journal of Water Process Engineering
M1 - 102070
ER -