Bacterial inactivation, photoreactivation and dark repair post flow-through pulsed UV disinfection

Kelly Fitzhenry, Eoghan Clifford, Neil Rowan, Angeles Val del Rio

    Research output: Contribution to journalArticlepeer-review

    25 Citations (Scopus)

    Abstract

    Pulsed UV (PUV) technology is accepted commercially for disinfection within the food packaging industry, but has yet to be deployed by the water/wastewater sector. This is partly due to a lack of robust, independently validated data for submerged or flow-through treatment applications. This study evaluated the efficacy of PUV for water disinfection under flow-through conditions. Bacterial pathogens of interest in the food and water/wastewater sector, namely Escherichia coli, Staphylococcus aureus and Listeria innocua (surrogate for L. monocytogenes) were used to investigate the potential for photoreactivation and/or dark repair post PUV flow-through disinfection. A continuous-flow low-pressure UV was also analysed under similar experimental conditions. Bacterial inactivation via flow-through PUV was dependant on energy output with E. coli exhibiting greatest sensitivity to PUV treatment (5.3 log 10 inactivation after treatment at 1539 mJ/cm 2 - output in UV range < 300 nm); L. innocua exhibited the highest PUV resistance (3.0 log 10 inactivation after treatment at 1539 mJ/cm 2 – output in UV range < 300 nm) under similar treatment conditions. Greater photoreactivation occurred at lower PUV outputs for both S. aureus and E. coli after flow-through PUV treatment. Thus exposure of treated bacteria to natural light, immediately post flow-through PUV treatment, should be avoided to minimise photoreactivation. The LPUV demonstrated inactivation of all bacteria below the limit of detection (1 CFU/mL) and inhibited the occurrence of photoreactivation. This study highlights the importance of considering bacterial repair potential and the need for further development of PUV technology for such applications.

    Original languageEnglish
    Article number102070
    JournalJournal of Water Process Engineering
    Volume41
    DOIs
    Publication statusPublished - Jun 2021

    Keywords

    • Bacterial disinfection
    • Cell injury
    • Disease mitigation
    • Pulsed UV
    • Ultraviolet applications
    • Wastewater treatment

    Fingerprint

    Dive into the research topics of 'Bacterial inactivation, photoreactivation and dark repair post flow-through pulsed UV disinfection'. Together they form a unique fingerprint.

    Cite this